dModule 2.5A/10V

Available modules:

Dual channel module for Ivium-n-Stat

Compliance on each channel: ±2.5A/±10V

Integrated impedance analyser in each channel as standard: 10µHz - 250kHz (1MHz optional)

You can buy this product from your local reseller:

Ivium Technologies B.V.

Contact resellerRequest information

Product description

Module

The dModule 2.5A/10V is a dual channel module for the Ivium-n-Stat which allows ±2.5A / ±10V compliance and simultaneous impedance measurements on each channel. IviumSoft allows control of separate channels or all channels simultaneously with a synchronized start. The module is encased in a protective housing for easy handling, and users can upgrade the number of channels in the Ivium-n-Stat in a simple plug and play manner.

Safety

The maximum current or potential of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.

Expandibility

Each channel can be expanded with various modules, such as a power booster, multiplexer, etc. See our compatibility table for reference.

Hardware

  • Automatic current range selection: 10nA to 1A/10mV to 10V
  • Automatic variable noise filter and potentiostat/galvanostat stability settings
  • Real time data display up to 500 pnts/s. Acquisition up to 100,000 pnts/s is stored in instrument memory
  • Applicable scanrates: 1µV/s to 10,000 V/s
  • Minimum interval time: 10µs (0.125µs resolution)
  • Result optimisation by automated tuned filters, gain amplifiers and DC-subtraction
  • User selectable floating operation

Channel Configurations

  • 2 x ±2.5A / ±10V

 

Read the full description

Specifications

System performance
Number of channels in module
2
Current compliance
±2.5A
Maximum compliance voltage
±10V
Maximum applied voltage
±10V
Electrode connections
4; WE, CE, RE, S (and GND) with 4mm banana plugs
Potentiostat bandwidth
>500kHz
Stability settings
High Speed, Standard and High Stability
Programmable response filter
1MHz, 100kHz, 10kHz, 1kHz, 10Hz
Signal acquisition
Dual channel 16bit ADC, 100,000 samples/s
Potentiostat
Applied potential range
±10V, with 0.33mV res.
Applied potential accuracy
0.2%, or 2mV
Current ranges
±10nA to ±1A in 9 decades
Measured current resolution
0.015% of current range, minimum 1.5pA
Measured current accuracy
0.2%
Galvanostat
Applied current resolution
0.033% of applied current range
Applied current accuracy
0.2%
Galvanostatic current ranges
±10nA to ±1A
Potential ranges
±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV,±1V, ±4V, ±10V
Measured potential resolution
0.03% of potential range, minimum 40nV
Measured potential accuracy
0.2% or 2mV
Impedance Analyser
Frequency range
10µHz to 250kHz (optional: 10µHz to 1MHz)
Amplitude
0.15mV to 1.0V, or 0.03% to 100% of current range
DC offset
16bit DC offset subtraction and 2 DC-decoupling filters
Electrometer
Input impedance
>1000Gohm //<10pF
Input bias current
<20pA
Bandwidth
>5MHz
Special functions
Ohmic drop compensation
2V/current range
Peripheral connections
Peripheral port
Not available
Environment
Size (w x d x h)
3 x 35 x 13cm
Weight
0.7kg
PC requirements
Windows 8/10, with free USB port
Specifications subject to change, Ivium Technologies ©2021

Available modules

dModule 2.5A/10V
qModule 30mA/10V
dModule 1A/20V
sModule 2.5A/10V
sModule 5A/10V
sModule 10A/5V
System performance
Number of channels in module
2
4
2
1
1
1
Current compliance
±2.5A
±30mA
±1A
±2.5A
±5A
±10A
Maximum compliance voltage
±10V
±10V
±20V
±10V
±10V
±5V
Maximum applied voltage
±10V
±10V
±10V
±10V
±10V
±5V
Potentiostat
Applied potential range
±10V, with 0.33mV res.
±10V, with 0.33mV res.
±10V, with 0.33mV res.
±10V, with 0.33mV res.
±10V, with 0.33mV res.
±5V, with 0.33mV res.
Current ranges
±10nA to ±1A in 9 decades
±10nA to ±10mA in 7 decades
±10nA to ±1A in 9 decades
±10nA to ±10A in 10 decades
±10nA to ±10A in 10 decades
±10nA to ±10A in 10 decades
Galvanostat
Galvanostatic current ranges
±10nA to ±1A
±10nA to ±10mA
±10nA to ±1A
±10nA to ±10A
±10nA to ±10A
±10nA to ±10A
Peripheral connections
Analog in/out
-
-
-
2/1 (±10V, 16bit resolution, bandwidth 40kHz/±10V, 16bit resolution)
2/1 (±10V, 16bit resolution, bandwidth 40kHz/±10V, 16bit resolution)
2/1 (±10V, 16bit resolution, bandwidth 40kHz/±10V, 16bit resolution)
Digital input/output
-
-
-
1/3 (0 to +5V)
1/3 (0 to +5V)
1/3 (0 to +5V)
I-out/E-out
-
-
-
Analog monitor for cell current and potential
Analog monitor for cell current and potential
Analog monitor for cell current and potential
AC-out
-
-
-
±0.5V sinewave 10µHz-250kHz with variable attenuation
±0.5V sinewave 10µHz-250kHz with variable attenuation
±0.5V sinewave 10µHz-250kHz with variable attenuation
Channel-X input, Channel-Y input
-
-
-
±4V: to record impedance from peripheral devices
±4V: to record impedance from peripheral devices
±4V: to record impedance from peripheral devices
Peripheral port
Not available
Not available
Not available
Yes
Yes
Yes

Postal address

  • Ivium Technologies B.V.
  • De Zaale 11
  • 5612 AJ Eindhoven
  • The Netherlands

Visiting address

  • Ivium Technologies B.V.
  • De Lismortel 31
  • 5612 AR Eindhoven
  • The Netherlands

Contact