Innovative solutions for electrochemical research
pocketSTAT2

pocketSTAT2

Scan range: ±30mA/±10V

FRA/EIS: 10µHz-1MHz

Size: 16 x 6.7 x 1.9cm

Weight: 300g

Buy from your local reseller (US):

Nanoscience Instruments

Contact resellerRequest information

Product description

Handheld
The pocketSTAT2 is a portable potentiostat/galvanostat/ZRA with integrated FRA/EIS, and has the size and weight of a smart phone. It is controlled via a USB connection from any netbook, laptop or PC that is Windows operated.

Key specifications 
– Size: 16 x 6.7 x 1.9cm
– Weight: 300g
– Scan range: ±10V/±30mA
– 4 Electrode connection: WE/CE/RE/S and GND lead
– Max. acquisition rate: 300,000 pnts/s

Rugged design
The pocketSTAT2 has a housing made of strong, yet lightweight aluminium.

Hardware

  • Automatic current range selection: 100pA to 10mA/1mV to 10V
  • Automatic variable noise filter and potentiostat/galvanostat stability settings
  • Real time data up to 3,000 pnts/s. Acquisition up to 300,000 pnts/s is stored in instrument memory
  • Applicable scanrates: 1µV/s to 10,000V/s
  • Minimum interval time: 3.33µs (0.125µs resolution)
  • Result optimalisation by automated tuned filters, gain amplifiers and DC-subtraction

Software:
The pocketSTAT2 is controlled via Ivium’s own IviumSoft. This versatile, yet intuitive software package allows instrument control, data management and analysis, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is included with each instrument as standard.

Read the full description

Specifications

System performance
Current compliance
±30mA
Maximum compliance voltage
±10V
Maximum applied voltage
±10V
Electrode connections
4; WE, CE, RE, S (and GND) with 4mm banana plugs
Potentiostat bandwidth
>500kHz
Stability settings
High Speed, Standard and High Stability
Programmable response filter
1MHz, 100kHz, 10kHz, 1kHz, 10Hz
Signal acquisition
Dual channel 18bit ADC, 300,000 samples/s stored in instrument memory (max. 1M datapoints)
Potentiostat
Applied potential range
±10V, 0.08mV res.
Applied potential accuracy
0.2%, or 2mV
Current ranges
±100pA to ±10mA in 9 decades
Measured current resolution
0.003% of current range, minimum 3fA
Measured current accuracy
20pA + 0.025% of FSR
Galvanostat
Applied current resolution
0.008% of applied current range
Applied current accuracy
0.2%
Galvanostatic current ranges
±10nA to ±10mA
Potential ranges
±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV, ±1V, ±4V, ±10V
Measured potential resolution
0.0008% of potential range, minimum 7nV
Measured potential accuracy
0.2% or 2mV
Impedance Analyser
Frequency range
10µHz to 1MHz
Amplitude
0.15mV to 2.0V, or 0.03% to 100% of current range
DC offset
16bit DC offset subtraction and 2 DC-decoupling filters
Electrometer
Input impedance
>1000Gohm //<10pF
Input bias current
<20pA
Bandwidth
>5MHz
Special functions
Ohmic drop compensation
2V/current range
Peripheral connections
Analog in/out
±10V input only, 16bit resolution, bandwidth 40kHz (*not available with cell cable delivered as standard)
Environment
Power requirements
Via USB
Interfacing
USB
Size (w x d x h)
16 x 6.7 x 1.9cm
Weight
300g
PC requirements
Windows 8/10/11, with free USB port
Specifications subject to change, Ivium Technologies ©2024

Need help?

Our experts are ready to answer your questions.

Information request

Postal address

  • Ivium Technologies B.V.
  • De Zaale 11
  • 5612 AJ Eindhoven
  • The Netherlands

Visiting address

  • Ivium Technologies B.V.
  • De Lismortel 31
  • 5612 AR Eindhoven
  • The Netherlands

Contact

  • T +31 40 2390600
  • F
  • E info@ivium.com
©2024 Ivium Technologies B.V.